  • 美国CIRS 002HN放疗测试体模主要用于头部和脖子的放疗测试。

     

    美国CIRS 002HN放疗测试体模产品简介:

    The CIRS Model 002HN IMRT phantom is designed to address the complex issuessurrounding commissioning and comparison of treatment planning systems andverification of individual patient plans and delivery.

    The CIRS 002HN phantom properly represents human head and neck anatomy inshape, proportion and structure as well as density. This enables thoroughanalysis of both the treatment planning and delivery systems. The phantom isconstructed of proprietary tissue equivalent epoxy materials. Linearattenuations of the simulated tissues are within 1% of actual attenuation forbone and water from 50 keV to 15 MeV.

    The phantom is circular in shape, approximates the size of an averagepatient. Tissue equivalent interchangeable rod inserts for ionization chambersallow for point dose measurements in multiple planes in the phantom and filmcalibration.* The phantom also supports film dosimetry with not only standardradiographic films but also GafChromic®media. Additional inserts are availableto support a variety of other detectors including TLD’s, MOSFET, and diodes.

    The Model 002HN accommodates one Ready PackTM 10” x 12” films in transverseorientation, two radiochromic or radiographic 10 x 10 cm films in transverseorientation and a stack of thirteen radiochromic films pre-cut to 63.5 x 63.5 mmin three different orientations.

    The Model 002HN has an optional four Electron Density reference plugs whichcan be interchanged in five separate locations within the phantom. The surfaceof the phantom is etched with grooves to ensure proper orientation of the CTslices and accurate film to plan registration. An optional cranial bone ring isalso available.

     

    美国CIRS 002HN放疗测试体模产品特点:

    Verify heterogeneity corrections

    Correlate CTU to electron density

    Check dose distributions in sensitive areas

    Check depth doses and absolute dose

    2D and 3D isodoses

    Calibrate film with ion chamber*

    Verify individual patient treatment plans

    IMRT Verification System

    CIRS IMRT phantoms are manufactured from tissue equivalent materials thatmimic within 1% from 50 keV to 15 MeV for accurate simulation from CT planningto treatment delivery. The interchangeable rod design allows the phantom toaccommodate a multitude of dose measurement devices such as ion chambers, TLD,diodes and MOSFET's in the same location within the phantom. Phantom crosssections accommodate GafChromic® or standard ready-pack films.

    *NOTE: This product or an optional accessory of this product requires a CIRSdosimetry cavity code before an order can be placed. Please refer to theDosimetry Cavity Codes document to identify the CIRS code for the probe youintend to use with this product.

    The CIRS line of IMRT phantoms is compatible with the RIT 113 software forfilm to plan analysis. GafChromic® is a registered trademark of InternationalSpecialty Products, Wayne, NJ.

    搜好货厂家上海浦予工业科技有限公司为您提供美国CIRS 002HN放疗测试体模的详细产品价格、产品图片等产品介绍信息,您可以直接联系厂家获取美国CIRS 002HN放疗测试体模的具体资料,联系时请说明是在搜好货网看到的。

    加工定制 :
    类型 : 放疗测试体模
    品牌 : 美国CIRS
    型号 : 002HN
    产品用途 : 广泛
    可售地 : 全国
    精品推荐
    您还可以找
    搜好货网 > 上海浦予工业科技有限公司 > 美国CIRS 002HN放疗测试体模